Service Description:

Geothermal Vertical Closed Loop suitability map.

Ground source heat energy, sometimes called shallow geothermal energy, can be collected from the ground and boosted with heat pumps. This can yield up to four times as much energy as is used to collect it, giving ‘four for the price of one’ in energy terms. Heat energy can be harnessed, or ‘collected’, using different types of collector systems:

Closed loop collectors are systems where heat is extracted from the ground (or cooling is gained) by pumping a heat exchange fluid through closed pipes within the ground. The pipes can be installed borehole(s) (vertical closed loop) or laid out horizontally (horizontal closed loop).

Open loop ground source heat systems operate by taking heat energy from abstracted groundwater using a heat pump. The volume of groundwater that can be abstracted from a borehole or taken from a spring each day (the ‘yield’) determines the total amount of heat energy available, and therefore the size of heat pump that can be used and the size of building that can be heated.

The ground source heating/cooling suitability maps indicate which type of ground source heat collector is most compatible with the geology below your site. All maps should be assessed together, since whilst some areas may be unsuitable for one type of ground source heat collector system (‘ground source heat pumps’ or GSHPs), the heat energy can be successfully harnessed by a different type of system. The maps show that there is a shallow geothermal solution for heating or cooling for every location in Ireland.

The suitability maps use a suitability rating ranging from 1 (worst) to 5 (best) for each type of heat collector/cooling system. Suitability maps for open loop (domestic/small commercial), open loop (larger commercial/industrial processes) and vertical closed loop systems are available.

This map is to the scale 1:40,000. This means it should be viewed at that scale. When printed at that scale 1cm on the map relates to a distance of 400m.

It is a vector dataset. Vector data portray the world using points, lines, and polygons (areas).

The data is shown as polygons. Each polygon holds information on: Suitability Class and Suitability Description.



All Layers and Tables

Has Versioned Data: false

MaxRecordCount: 2000

Supported Query Formats: JSON

Supports Query Data Elements: true

Layers: Description: Geothermal Vertical Closed Loop suitability map.Ground source heat energy, sometimes called shallow geothermal energy, can be collected from the ground and boosted with heat pumps. This can yield up to four times as much energy as is used to collect it, giving ‘four for the price of one’ in energy terms. Heat energy can be harnessed, or ‘collected’, using different types of collector systems:Closed loop collectors are systems where heat is extracted from the ground (or cooling is gained) by pumping a heat exchange fluid through closed pipes within the ground. The pipes can be installed borehole(s) (vertical closed loop) or laid out horizontally (horizontal closed loop).Open loop ground source heat systems operate by taking heat energy from abstracted groundwater using a heat pump. The volume of groundwater that can be abstracted from a borehole or taken from a spring each day (the ‘yield’) determines the total amount of heat energy available, and therefore the size of heat pump that can be used and the size of building that can be heated.The ground source heating/cooling suitability maps indicate which type of ground source heat collector is most compatible with the geology below your site. All maps should be assessed together, since whilst some areas may be unsuitable for one type of ground source heat collector system (‘ground source heat pumps’ or GSHPs), the heat energy can be successfully harnessed by a different type of system. The maps show that there is a shallow geothermal solution for heating or cooling for every location in Ireland.The suitability maps use a suitability rating ranging from 1 (worst) to 5 (best) for each type of heat collector/cooling system. Suitability maps for open loop (domestic/small commercial), open loop (larger commercial/industrial processes) and vertical closed loop systems are available.This map is to the scale 1:40,000. This means it should be viewed at that scale. When printed at that scale 1cm on the map relates to a distance of 400m.It is a vector dataset. Vector data portray the world using points, lines, and polygons (areas).The data is shown as polygons. Each polygon holds information on: Suitability Class and Suitability Description.

Service Item Id: 62734914d6cf461194e6ce8f2917b1bb

Copyright Text: Geological Survey Ireland

Spatial Reference: 2157  (2157)


Initial Extent: Full Extent: Units: esriMeters

Document Info: Enable Z Defaults: false

Supports ApplyEdits With Global Ids: false

Support True Curves : true

Only Allow TrueCurve Updates By TrueCurveClients : true

Supports Return Service Edits Option : true

Supports Dynamic Layers: false

Child Resources:   Info   Query Data Elements   Relationships

Supported Operations:   Query   Query Contingent Values   QueryDomains   Create Replica   Extract Changes