Service Description: Geothermal Vertical Closed Loop suitability map.
Ground source heat energy, sometimes called shallow geothermal energy, can be collected from the ground and boosted with heat pumps. This can yield up to four times as much energy as is used to collect it, giving ‘four for the price of one’ in energy terms. Heat energy can be harnessed, or ‘collected’, using different types of collector systems:
Closed loop collectors are systems where heat is extracted from the ground (or cooling is gained) by pumping a heat exchange fluid through closed pipes within the ground. The pipes can be installed borehole(s) (vertical closed loop) or laid out horizontally (horizontal closed loop).
Open loop ground source heat systems operate by taking heat energy from abstracted groundwater using a heat pump. The volume of groundwater that can be abstracted from a borehole or taken from a spring each day (the ‘yield’) determines the total amount of heat energy available, and therefore the size of heat pump that can be used and the size of building that can be heated.
The ground source heating/cooling suitability maps indicate which type of ground source heat collector is most compatible with the geology below your site. All maps should be assessed together, since whilst some areas may be unsuitable for one type of ground source heat collector system (‘ground source heat pumps’ or GSHPs), the heat energy can be successfully harnessed by a different type of system. The maps show that there is a shallow geothermal solution for heating or cooling for every location in Ireland.
The suitability maps use a suitability rating ranging from 1 (worst) to 5 (best) for each type of heat collector/cooling system. Suitability maps for open loop (domestic/small commercial), open loop (larger commercial/industrial processes) and vertical closed loop systems are available.
This map is to the scale 1:40,000. This means it should be viewed at that scale. When printed at that scale 1cm on the map relates to a distance of 400m.
It is a vector dataset. Vector data portray the world using points, lines, and polygons (areas).
The data is shown as polygons. Each polygon holds information on: Suitability Class and Suitability Description.
Map Name: IE_GSI_Geothermal_Vertical_Closed_Loop_Suitability_40K_IE26_ITM
Legend
All Layers and Tables
Layers:
Description: Geothermal Vertical Closed Loop suitability map.Ground source heat energy, sometimes called shallow geothermal energy, can be collected from the ground and boosted with heat pumps. This can yield up to four times as much energy as is used to collect it, giving ‘four for the price of one’ in energy terms. Heat energy can be harnessed, or ‘collected’, using different types of collector systems:Closed loop collectors are systems where heat is extracted from the ground (or cooling is gained) by pumping a heat exchange fluid through closed pipes within the ground. The pipes can be installed borehole(s) (vertical closed loop) or laid out horizontally (horizontal closed loop).Open loop ground source heat systems operate by taking heat energy from abstracted groundwater using a heat pump. The volume of groundwater that can be abstracted from a borehole or taken from a spring each day (the ‘yield’) determines the total amount of heat energy available, and therefore the size of heat pump that can be used and the size of building that can be heated.The ground source heating/cooling suitability maps indicate which type of ground source heat collector is most compatible with the geology below your site. All maps should be assessed together, since whilst some areas may be unsuitable for one type of ground source heat collector system (‘ground source heat pumps’ or GSHPs), the heat energy can be successfully harnessed by a different type of system. The maps show that there is a shallow geothermal solution for heating or cooling for every location in Ireland.The suitability maps use a suitability rating ranging from 1 (worst) to 5 (best) for each type of heat collector/cooling system. Suitability maps for open loop (domestic/small commercial), open loop (larger commercial/industrial processes) and vertical closed loop systems are available.This map is to the scale 1:40,000. This means it should be viewed at that scale. When printed at that scale 1cm on the map relates to a distance of 400m.It is a vector dataset. Vector data portray the world using points, lines, and polygons (areas).The data is shown as polygons. Each polygon holds information on: Suitability Class and Suitability Description.
Service Item Id: 020c80c2f5ff4d20b0229a416e2ea860
Copyright Text: Geological Survey Ireland
Spatial Reference:
2157
(2157)
Single Fused Map Cache: true
Tile Info:
- Height: 256
- Width: 256
- DPI: 96
-
Levels of Detail: 13
- Format: PNG
- Compression Quality: 0.0
- Origin: X: -5022200.0
Y: 4821100.0
- Spatial Reference: 2157
(2157)
Initial Extent:
XMin: 341472.1635278177
YMin: 494054.0699342424
XMax: 842502.7004721824
YMax: 991301.2047657585
Spatial Reference: 2157
(2157)
Full Extent:
XMin: 417434.4497
YMin: 519727.1557
XMax: 766540.4143
YMax: 965628.119000001
Spatial Reference: 2157
(2157)
Units: esriMeters
Supported Image Format Types: PNG32,PNG24,PNG,JPG,DIB,TIFF,EMF,PS,PDF,GIF,SVG,SVGZ,BMP
Document Info:
Title: IE_GSI_Geothermal_Vertical_Closed_Loop_Suitability_40K_IE26_ITM
Author:
Comments:
Subject:
Category:
Keywords: Ireland,IE/GSI,Energy resources,Geothermal,Closed Loop,Vertical,geothermal energy
AntialiasingMode: None
TextAntialiasingMode: Force
Supports Dynamic Layers: false
Resampling: false
MaxRecordCount: 2000
MaxImageHeight: 4096
MaxImageWidth: 4096
Supported Query Formats: JSON, geoJSON, PBF
Supports Query Data Elements: true
Min Scale: 4000000
Max Scale: 2500
Supports Datum Transformation: true
Child Resources:
Info
Supported Operations:
Export Map
Identify
QueryDomains
QueryLegends
Find
Return Updates